WAKOL TS 102 Footfall Soundproofing Mat - 2 mm
WAKOL TS 102 Footfall Soundproofing Mat - 3 mm: is used for improving the footfall soundproofing and heat insulation of flooring structures in old and new buildings. WAKOL TS 102 is suitable as soundproofing material under PVC, CV, textile, linoleum and caoutchouc flooring, as well as strip, multi-layer parquet, wood block RE/WE, solid wood planks and stratified flooring indoors.
WAKOL TS 102 Footfall Soundproofing Mat - 3 mm
WAKOL TS 102 Footfall Soundproofing Mat - 3 mm: is used for improving the footfall soundproofing and heat insulation of flooring structures in old and new buildings. WAKOL TS 102 is suitable as soundproofing material under PVC, CV, textile, linoleum and caoutchouc flooring, as well as strip, multi-layer parquet, wood block RE/WE, solid wood planks and stratified flooring indoors.
Area of application
Cork/polyurethane foam matting for improving the footfall sound and heat insulation of floor covering constructions in old and new buildings. WAKOL TS 103 Footfall Soundproofing Mat, 3 mm, is suitable as a soundproofing plate underneath:
- Â PVC and CV flooring;
- Â textile flooring;
- Â linoleum flooring;
- Â rubber floor coverings;
- Â mosaic parquet (cubed pattern) according to DIN EN 13488;
- on-edge lamella parquet according to DIN EN 14761;
- strip parquet according to DIN EN 13226;
- multi-layer parquet according to DIN EN 13489;
- wood-block RE / WE according to DIN 68702;
- Â solid wood planks (oak wood type, max. 16 cm in width) according to DIN EN 13226 and DIN EN 13990;
- Â laminate;
- Â indoors;
- Â suitable for chair rollers;
- Â suitable for underfloor heating.
Technical data:
Raw material basis: | Permanently elastic composite material made of cork and PU foam granules |
Delivery: | roll |
Dimensions: | 35 m in length, 1 m in width |
Material thickness: | 2 mm |
Mass per unit area: | approx. 0.91 kg/m² |
Footfall sound reduction: (according to EN ISO 140-8) |
19 dB in combination with 10 mm multi-layer parquet 19 dB in combination with 3 mm PVC 17 dB in combination with 3 mm rubber |
Note on storage: | The rolls must be stored upright |
Reaction to fire: (according to ISO 11925/EN 13501) |
Efl |
Thermal resistance: R (according to EN 12667) |
0.03 m² K/W |
EMICODE according to GEV: | EC1 |
Subfloors
The subfloor and the climatic conditions of the room must meet the requirements of DIN 18356 or DIN 18365. Subfloors must be level, permanently dry, solid, and free from dirt and adhesion-inhibiting substances.
Apply appropriate Wakol levelling compounds to uneven subfloors. The technical information on the primers and levelling compounds must be heeded.
Usage
Bonding the footfall soundproofing mat:
WAKOL TS 102 Footfall Soundproofing Mat, 2 mm, must be bonded close together on the prepared subfloor diagonally to the floor covering strip with the same adhesive used for the top covering. Apply the adhesive with a TKB A2, B1 or B2 notched trowel (parquet). Fit soundproofing plate following appropriate airing time and press down well. Rub down a short time later. Laying of the top covering can occur on the next day, after the adhesive has set.
Bonding of the top covering:
Before laying PVC and CV flooring or rubber and linoleum flooring, level out the soundproofing plate in the system with WAKOL D 3050 Plastification Additive.
Sand the compound layer after hardening. Textile flooring, laminate and parquet are bonded directly to the soundproofing plate without levelling compound.
The following products are suitable for bonding:
PVC flooring, homogeneous: | WAKOL D 3318 MultiFlex, fibre-containing, WAKOL D 3320 PVC Adhesive, WAKOL D 3360 VersaTack |
CV flooring: | WAKOL D 3318 MultiFlex, fibre-containing, WAKOL D 3320 PVC Adhesive, WAKOL D 3360 VersaTack |
Textile flooring: | WAKOL D 3304 Linoleum Adhesive, WAKOL D 3308 Carpet Adhesive, WAKOL D 3309 Carpet Adhesive, WAKOL D 3360 VersaTack |
Linoleum: | WAKOL D 3304 Linoleum Adhesive |
Rubber floor coverings: | WAKOL D 3410 Kontakto (contact bonding), WAKOL PU 270 Polyurethane Adhesive |
Strip parquet, Solid wood planks: | WAKOL MS 260 Parquet Adhesive, firm-elastic, WAKOL MS 290 Parquet Adhesive, WAKOL PU 210 Parquet Adhesive, WAKOL PU 215 Parquet Adhesive, WAKOL PU 225 Parquet Adhesive, WAKOL PU 390 Parquet Adhesive |
Multi-layer parquet: | WAKOL MS 230 Parquet Adhesive, elastic, WAKOL MS 240 Parquet Adhesive, elastic, WAKOL MS 260 Parquet Adhesive, firm-elastic, WAKOL MS 290 Parquet Adhesive, WAKOL PU 210 Parquet Adhesive, WAKOL PU 215 Parquet Adhesive, WAKOL PU 225 Parquet Adhesive, WAKOL PU 390 Parquet Adhesive |
Laminate: (must be approved by the manufacturer for bonding)) |
WAKOL PU 210 Parquet Adhesive, WAKOL PU 225 Parquet Adhesive |
Important
Do not use at temperatures below +15 °C. In cold weather, warm up WAKOL TS 102 Footfall Soundproofing Mat, 2 mm, in due time in a heated room. All information is based on approx. 20 °C and 65 % relative air humidity.
If paint is to be used, first clarify its suitability for parquet bonding on an elastic underlay mat.
The producer guarantee the uniform high quality of their products. All data are based on tests and many years of practical experience and refer to standardised conditions. The variety of materials used and the different construction site conditions, which lie beyond our control, preclude any claims based on this data. We therefore recommend making sufficient trials. Accompanying flooring manufacturer's instructions and the currently applicable standards and codes must be observed.
We also gladly provide technical advice.
Video presentation from Wakol:
Each wood flooring project is different so an individual approach is a must for us. We've created this cost calculator with this in mind and we hope it will be helpful to you in bringing some much-needed clarity.
Please fill in as many fields as possible with the most accurate and available information. This will increase the quality of the end result.